Changes in Intraocular Pressure following Narcosis With Medetomidine, Midazolam, and Fentanyl in Association With Initial Intraocular Pressure in Mice

M Binter, P Lüdtke, F Langer, T Schigiel… - Current Eye …, 2022 - Taylor & Francis
… , individual animals, conditioning, and mice restraining.Citation 8 … in conscious C57BL/6J
mice and 7 mmHg compared to … study is the iCare TonoLab rebound tonometer. It inherits the …

Differential intraocular pressure measurements by tonometry and direct cannulation after treatment with soluble adenylyl cyclase inhibitors

JK Gandhi, U Roy Chowdhury, Z Manzar… - Journal of Ocular …, 2017 - liebertpub.com
anesthesia to avoid unknown and confounding effects of the … measured by rebound tonometry
in nonanesthetized mice. … the effect on IOP of KH7 in conscious versus anesthetized mice, …

[HTML][HTML] Effect of anesthesia on intraocular pressure measured with continuous wireless telemetry in nonhuman primates

JV Jasien, CA Girkin, JC Downs - … ophthalmology & visual …, 2019 - tvst.arvojournals.org
… IOP is acutely elevated as a result. Continuous IOP measurement via implanted transducers
also has the advantage of avoiding ocular … with tonometers that rely on corneal applanation. …

[HTML][HTML] Comparison of laser and circumlimbal suture induced elevation of intraocular pressure in albino CD-1 mice

HH Liu, L Zhang, M Shi, L Chen, JG Flanagan - PloS one, 2017 - journals.plos.org
acute transient models and chronic models of ocular hypertension … in our study to avoid the
confounding effect, ageing [26] … out in conscious animals with a Tonolab tonometer (iCare, …

[HTML][HTML] … between the rebound (TD - 8000 portable) and applanation tonometer (Tono-Pen AviaTM) managed by different evaluators for intraocular pressure …

VTS Almeida, CB Garcia, AT Jorge, D Paulino… - Ciência Animal …, 2022 - SciELO Brasil
… values of intraocular pressure (IOP) by different tonometers and … Rebound tonometry in
conscious, conditioned mice avoids the acute and profound effects of anesthesia on intraocular

[HTML][HTML] Reference values for selected ophthalmic tests of the blue-and-yellow macaw (Ara ararauna)

MSA Falcão, RV Monteiro, CM Carvalho… - Pesquisa Veterinária …, 2017 - SciELO Brasil
… for intraocular pressure measured by rebound tonometry in ten … Evaluation of intraocular
pressure in conscious ferrets (… Rebound Tonometry in Conscious, Conditioned Mice Avoids

[HTML][HTML] A new mouse-fixation device for IOP measurement in awake mice

J Guo, J Yang, H Huang, K Wu, X Wu, H Wang, Y He… - Vision Research, 2024 - Elsevier
… High intraocular pressure (IOP) is an established risk factor … Moreover, this method cannot
be applied to conscious mice. … To avoid potential problems with anesthetics, mouse IOPs can …

ChAPTeR 5 Y eFFeCT OF ANeSTheSIA ON INTRAOCULAR PReSSURe meASUReD WITh CONTINUOUS WIReLeSS TeLemeTRY IN NONhUmAN PRImATeS

JV JASIeN, CA GIRKIN… - … OF INTRAOCULAR …, 2019 - search.proquest.com
… , but not outflow facility in mice. Curr … Rebound tonometry in conscious, conditioned
mice avoids the acute and profound effects of anesthesia on …

A comparison of applanation and rebound tonometers in young chicks

LA Ostrin, CF Wildsoet - Current eye research, 2021 - Taylor & Francis
… and rebound tonometry readings of intraocular pressure in … , general anesthesia can generally
also be avoided and so … current study was designed for use with mice and rats, with two …

[HTML][HTML] Effect of αvβ3 integrin expression and activity on intraocular pressure

JA Faralli, MS Filla, DM Peters - Investigative ophthalmology & …, 2019 - arvojournals.org
… IOP was measured weekly for 11 weeks using rebound tonometry. Mice were then killed …
9–11 AM) 3 to 5 minutes after anesthesia administration using a rodent Icare Tonolab. Previous …